CN
Ring main unit core original
Product

Ring main unit core original
Unique Products

  • SHV-12/630A gas charging cabinet circuit breaker (with isolation belt grounding)

    SHV-12/630A gas charging cabinet circuit breaker (with isolation belt grounding)

    SHV-12/630A circuit breaker switch has the advantages of easy installation, less maintenance, long service life, small size, low price, safety and reliability. This product meets the technical requirements of GB1984-89 and GB/T1984-2003 AC high-voltage circuit breakers. Main circuit 630A-20KA, 25KA, mechanical life 10000 times. Grounding circuit 20KA, mechanical life: circuit breaker 10000 times, isolation/grounding: 3000 times/3000 times.

    More

  • SHV-12/630A inflatable cabinet router (without isolation and grounding)

    SHV-12/630A inflatable cabinet router (without isolation and grounding)

    ◆ The altitude shall not exceed 2000m, and the seismic intensity shall not exceed 8 degrees. ◆ The ambient air temperature is lower than+40 ℃ and not lower than - 30 ℃. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%. ◆ The installation site with frequent violent vibration, water vapor, gas, chemical corrosive deposition, salt mist, dust, dirt, fire and explosion hazard that obviously affect the performance of the mechanism, is not suitable for use.

    More

  • SHC-12KV-630A load switch

    SHC-12KV-630A load switch

    SHC-12KV-630A load switch meets the relevant requirements of 3.6KV~40.5kV High Voltage AC Load Switch (GB3804-2004) and AC High Voltage Load Switch Fuse Combination Apparatus (GB16926-1997). Main circuit: 630A-20KA, 25KA; Mechanical life: 5000 times; Grounding circuit: 20KA; Mechanical life: 5000 times.

    More

  • SHG-12D 630A gas charging cabinet isolating switch

    SHG-12D 630A gas charging cabinet isolating switch

    ◆ The altitude shall not exceed 2000m, and the seismic intensity shall not exceed 8 degrees. ◆ The ambient air temperature is lower than+40 ℃ and not lower than 30 ℃. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%. ◆ The installation site with frequent violent vibration, water vapor, gas, chemical corrosive deposition, salt mist, dust, dirt, fire and explosion hazard that obviously affect the performance of the mechanism, is not suitable for use.

    More

Copyright © Shenheng Power Equipment Co., Ltd. All rights reserved | 浙ICP备2022020872号 | The website construction: SONSCHN wenzhou

Shenheng Power Equipment Co., Ltd.

0577-62633718